| Application | Indoor, Outdoor |
|---|---|
| IP Rating | IP54 |
| Material | Metal Steel |
SNR Metal Recessed Electrical Enclosure With Inner door
Categories All Products, Concealed Distribution Box, Metal Enclosure
Tag SNR
Features of product
- The cold-rolled steel casing is treated with an immersion primer coating and a powder coating, providing functional anti-corrosion protection.
- Standard sizes feature inner door, suitable for single-phase and three-phase systems.
- Compatible with mainstream MCB brands, compatible with the maximum busar capacity 100A~225A.
- The interior features a flexible design with a galvanized mounting plate, which facilitates the assembly of electrical control systems.
- The enclosures are fitted with quality locks (such as models MS705, MS306, MS308, AB403) for easy operation.
- Available in wall thicknesses of 1.0, 1.2, 1.5, and 2.0 mm.
| Item | Information |
|---|---|
| Material | SS304/ 316L/ Cold-rolled steel/ Galvanized Steel/ Alum choices |
| Surface treatment | Wiring drawing/ Spray powder coating/ Anodizing choices |
| Busbar capacity | 100A~225A |
| Mounting plate | Galvanized mounting plate |
| Color | RAL7032 or RAL7035 |
| Installation way | Recessed(Support surface model) |
| Assembling | MCCB/MCB Brand Options |
Specification of product
| No. | Order number | H=Height | W=Width | D=Depth | Enclosure Thickness | Max. Busbar Capacity (A) | No. of rows | 1P MCB for Each row(Way) |
|---|---|---|---|---|---|---|---|---|
| 1 | SNR705514 | 700 | 550 | 140 | 1.2/1.5mm | 100A~225A | 3 | 8~10 |
| 2 | SNR706014 | 700 | 600 | 140 | 1.2/1.5mm | 100A~225A | 3 | 9~12 |
| 3 | SNR706514 | 700 | 650 | 140 | 1.2/1.5mm | 100A~225A | 3 | 14~16 |
| 4 | SNR707014 | 700 | 700 | 140 | 1.2/1.5mm | 100A~225A | 3 | 16~18 |
| 5 | SNR856014 | 850 | 600 | 140 | 1.2/1.5mm | 100A~225A | 4 | 12~16 |
| 6 | SNR856514 | 850 | 650 | 140 | 1.2/1.5mm | 100A~225A | 4 | 14~18 |
| 7 | SNR857014 | 850 | 700 | 140 | 1.2/1.5mm | 100A~225A | 4 | 16~20 |
Don't have the size you need? Please submit the data here
Related products
FAQ
What to Consider for Custom Electrical Enclosure Design?
- Structure & Size:Determine size based on installation site, allowing room for operation/maintenance. Use robust materials like cold-rolled steel (1.2-2.0mm) or stainless steel.
- Electrical Performance:Select the appropriate enclosure specifications based on the voltage, current, frequency, and other parameters of the connected equipment.
- Environmental Adaptability:Select the appropriate IP rating based on the installation environment, such as IP54 (dust and water protected) or IP66 (dust-tight and protected against powerful water jets). In chemically corrosive environments, use stainless steel materials or surface zinc plating to extend the enclosure’s service life.
- Heat Dissipation and Ventilation:Incorporate ventilation holes or slots in appropriate areas of the enclosure to prevent excessive internal temperatures.
- Mechanical Structure and Handling:Choose suitable door type (front/side/rear) for easy maintenance. Include lifting hooks for portability. Eliminate sharp edges for operator protection.
How we Manufacture your Custom Electrical Enclosures?
- Confirming the Application Environment:We will communicate with you to understand the specific application scenario of your project. Based on this, we will provide recommendations for suitable materials for the custom electrical enclosure, such as waterproof stainless steel, painted cold-rolled steel, or galvanized steel.
- Confirming Internal Components:We will work with you to confirm the spatial requirements and layout of the internal devices. This allows us to select the appropriate enclosure size and internal configuration to house all components effectively.
- Selecting the Appropriate IP Rating:We will determine the necessary Ingress Protection (IP) rating based on whether the enclosure will be installed indoors or outdoors. The enclosure will then be manufactured to meet the specifications of the required IP standard.
- Choosing a Surface Finish:To meet both functional and aesthetic needs, we offer personalized surface treatment options. These include high-quality color powder coating or an all-over brushed finish for stainless steel. We can also accommodate brand identity requirements by providing custom logo.
How do we provide electrical system services to you?
- Please provide the circuit diagram and application scenario for your project. Our professional engineers will then assess the feasibility of the electrical system design and confirm the assembly plan.
- You can opt for us to assemble your electrical system using branded components (e.g., MCBs, MCCBs, Sockets, Lithium Batteries). Alternatively, provide your Bill of Materials, and we will manage the procurement and assembly.
- The complete system will be assembled by professional engineers and undergo electrical continuity testing to ensure proper circuitry.
SYNNOR
Manufacturing Capacity
Electrical Enclosure Laser Cutting
±0.05mm precision with smooth, burr-free edges and scratch-free surfaces. High-performance laser cutting, simplified
Electrical Enclosure Welding
Argon Arc Welding delivers cleaner, stronger, and higher quality welds and it prevents oxidation for flawless results on metals like stainless steel
Electrical Enclosure Bending
Professional bending machine makes bending accuracy ± 0.5mm, even different designs of junction box
Electrical Enclosure Foaming
High speed and accuracy foaming machines to make rubber ring for the electrical enclosure
Electrical Enclosure Printing
Electrostatic Spray Painting achieve a flawless, durable finish with maximum efficiency. It ensures even coverage on every surface
Electrical Enclosure Assembling
Support Electrical system assembling with Branded components